Conbextra Deep Pour FC501070-20KG

Conbextra Deep Pour FC501070-20KG
  • Conbextra Deep Pour FC501070-20KG

Conbextra Deep Pour

Conbextra Deep Pour is a high flow, dual shrinkage compensated cementitious grout for grouting applications ranging from 20 mm up to a maximum of 500 mm deep.

Typical Applications

  • Grouting applications where deep sections up to 500mm exist

Advantages

  • Unique non-metallic dual expansion system
  • compensates for shrinkage in both the plastic and hardened states
  • Excellent initial flow and flow retention
  • High ultimate strength and low permeability ensure durability of the hardened grout
  • Hydrogen-free gaseous expansion
  • Chloride free
  • Suitable for pumping or pouring over a large range of application consistencies and temperatures
  • 28 day strength @ 20°C dependent on consistency (cube samples) : 60-65 MPa
  • Application method : Pump or pour
  • Chemical resistance : Not resistant to acids - use epoxy grouts
  • Flexural Strength (modulus of rupture) @ 28 days : 75 MPa
  • Gap size : 20mm to 500mm
  • Indirect tensile strength @ 28 days : 4 MPa
  • Service temperature : >200°C
  • Set time : 9 hours
  • Tack free time : 500 mm

Overview

Typical Applications

  • Grouting applications where deep sections up to 500mm exist

Advantages

  • Unique non-metallic dual expansion system
  • compensates for shrinkage in both the plastic and hardened states
  • Excellent initial flow and flow retention
  • High ultimate strength and low permeability ensure durability of the hardened grout
  • Hydrogen-free gaseous expansion
  • Chloride free
  • Suitable for pumping or pouring over a large range of application consistencies and temperatures

Key Properties

  • 28 day strength @ 20°C dependent on consistency (cube samples) : 60-65 MPa
  • Application method : Pump or pour
  • Chemical resistance : Not resistant to acids - use epoxy grouts
  • Flexural Strength (modulus of rupture) @ 28 days : 75 MPa
  • Gap size : 20mm to 500mm
  • Indirect tensile strength @ 28 days : 4 MPa
  • Service temperature : >200°C
  • Set time : 9 hours
  • Tack free time : 500 mm

Application Guides

Spec Clause

Brochures

Technical Data Sheet

Conbextra Deep Pour TDS

Safety Data Sheet